--- title: "Core Real-Time Data" slug: "core-real-time-data" updated: 2026-08-12T02:10:07Z published: 2026-08-12T02:10:07Z canonical: "docs.bazefield.com/core-real-time-data" stale: true --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.bazefield.com/llms.txt > Use this file to discover all available pages before exploring further. # Core Real-Time Data ### **Overview** The *Core Real-Time Data* is a Certified Product Point Template for [Battery Management Systems](/product/docs/battery-management-system) that defines the standardized, minimum set of telemetry (e.g. time series points) Bazefield recommends for real-time monitoring of all [battery management systems](/product/docs/battery-management-system). These points ensure consistent data collection, improve interoperability across assets, and enable accurate reporting and analysis across your portfolio. This point template provides a reliable baseline of real-time data expected from each [Battery Management System](/product/docs/battery-management-system) modeled in Bazefield. The purpose is to: - Ensure consistent naming and normalization of critical telemetry available on all makes and models of [battery management systems](/product/docs/battery-management-system) - Streamline configuration for SCADA or historian data ingestion - Support cross-site and cross-technology data normalization The Core Real-Time Data template defines 13 standard data streams for Battery Management Systems. A Bazefield Battery Management System is an optional intermediate level in the ESS hierarchy, representing a BMS controller that manages one or more battery racks/strings and reports aggregated state and health data. Not all BESS architectures include a dedicated BMS level. ### **Template Definition** The *Core Real-Time Data* template contains standard data streams for Battery Management System SCADA data. Details on the Point Names, Descriptions, and Types are below. The *Core Real-Time Data* template specifically holds all the critical “raw” data expected from all Battery Management System SCADA systems. > **Minimum Requirements:** In most modern battery management systems, there will be a significant number of points available beyond this list which are vendor or SCADA specific. This list represents the minimum, common list of critical data often available in ALL vendors and SCADA systems. Many of the points below are used directly in Bazefield core functionality, or core performance calculations. Required for Bazefield Core Dashboard functionality Optional for common additional data streams/sources ### **Point Definition Table** | Name | Description | Type | Unit | | | --- | --- | --- | --- | --- | | CellTempAvg | Average cell temperature across managed module group | Raw Data | °C | | | CellTempMax | Maximum cell temperature across managed module group | Raw Data | °C | | | CellTempMin | Minimum cell temperature across managed module group | Raw Data | °C | | | CellVoltageAvg | Average cell voltage across managed module group | Raw Data | V | | | CellVoltageMax | Maximum cell voltage across managed module group | Raw Data | V | | | CellVoltageMin | Minimum cell voltage across managed module group | Raw Data | V | | | ChargeCurrentLimit | BMS-imposed charge current limit | Raw Data | A | | | Current | Module group DC bus current | Raw Data | A | | | DischargeCurrentLimit | BMS-imposed discharge current limit | Raw Data | A | | | OperationState | Raw OEM BMS operation state. To be mapped to IEC-OperationState via scale equation. | Raw Data | — | | | StateOfCharge | BMS-computed State of Charge for managed module group | Raw Data | % | | | StateOfHealth | BMS-computed State of Health for managed module group | Raw Data | % | | | Voltage | Module group total DC bus voltage | Raw Data | V | |