--- title: "Core Real-Time Data" slug: "core-real-time-data-meter" updated: 2025-10-27T20:14:54Z published: 2025-11-04T18:06:42Z canonical: "docs.bazefield.com/core-real-time-data-meter" --- > ## Documentation Index > Fetch the complete documentation index at: https://docs.bazefield.com/llms.txt > Use this file to discover all available pages before exploring further. # Core Real-Time Data ### Overview The *Core Real-Time Data* is a Certified Product Point Template for [Meter](/product/docs/meter) which defines the standardized, minimum set of telemetry (e.g. time series points) Bazefield recommends for real-time monitoring of all [Meters](/product/docs/meter). These points ensure consistent data collection, improve interoperability across assets, and enable accurate reporting and analysis across your portfolio. This point template provides a reliable baseline of real-time data expected from each [Meter](/product/docs/meter) modeled in Bazefield. The purpose is to: - Ensure consistent naming and normalization of critical telemetry available on all makes and models of [Meters](/product/docs/meter) - Streamline configuration for SCADA or historian data ingestion - Support cross-site and cross-technology data normalization ### Template Definition The [*Core Real-Time Data*](/product/docs/core-real-time-data-meter#overview) point template includes telemetry definitions for standard meter measurements. Meter data is useful at a site level, and is often compared to aggregations of generating asset data. Details on the Point Names, Descriptions, and Types are below. Required for Bazefield Core Dashboard functionality Optional for common additional data streams/sources | Name | Description | Type | Unit | | | --- | --- | --- | --- | --- | | ActivePower | Three phase active power total | SCADA (raw) | MW | | | ActivePowerA | Active power phase A | SCADA (raw) | MW | | | ActivePowerB | Active power phase B | SCADA (raw) | MW | | | ActivePowerC | Active power phase C | SCADA (raw) | MW | | | ApparentPower | Three phase apparent power total | SCADA (raw) | MVA | | | ApparentPowerA | Apparent power phase A | SCADA (raw) | MVA | | | ApparentPowerB | Apparent power phase B | SCADA (raw) | MVA | | | ApparentPowerC | Apparent power phase C | SCADA (raw) | MVA | | | CommunicationState | Communication state (Bazefield calculated) 1= bad comms | SCADA (raw) | | | | Current | Total current of three phases | SCADA (raw) | A | | | CurrentA | Current phase A | SCADA (raw) | A | | | CurrentB | Current phase B | SCADA (raw) | A | | | CurrentC | Current phase C | SCADA (raw) | A | | | Frequency | Frequency | SCADA (raw) | Hz | | | PowerFactor | Power factor | SCADA (raw) | % | | | PowerFactorA | Power factor phase A | SCADA (raw) | % | | | PowerFactorB | Power factor phase B | SCADA (raw) | % | | | PowerFactorC | Power factor phase C | SCADA (raw) | % | | | ReactivePower | Three phase reactive power total | SCADA (raw) | MVAR | | | ReactivePowerA | Reactive power phase A | SCADA (raw) | MVAR | | | ReactivePowerB | Reactive power phase B | SCADA (raw) | MVAR | | | ReactivePowerC | Reactive power phase C | SCADA (raw) | MVAR | | | TotalEnergyConsumed | Lifetime energy consumed | SCADA (raw) | MWh | | | TotalEnergyProduced | Lifetime energy produced | SCADA (raw) | MWh | | | Voltage | Average three phase line to line voltage | SCADA (raw) | kV | | | VoltageAB | Voltage line to line phase AB | SCADA (raw) | kV | | | VoltageAN | Voltage line to neutral phase A | SCADA (raw) | kV | | | VoltageBC | Voltage line to line phase BC | SCADA (raw) | kV | | | VoltageBN | Voltage line to neutral phase B | SCADA (raw) | kV | | | VoltageCA | Voltage line to line phase CA | SCADA (raw) | kV | | | VoltageCN | Voltage line to neutral phase C | SCADA (raw) | kV | |